Getting started

Start here

This page gets you from an empty .NET project to your first KEYENCE KV Host Link read. You will connect to your PLC at 192.168.250.100:8501, read DM0, then write and restore a test register.

Prerequisites

Requirement Value
.NET SDK .NET 9 SDK, matching the package target framework net9.0.
PLC network Your KV PLC must be reachable from your PC.
Host Link port Use port 8501 for TCP or UDP unless your PLC connection node is configured differently.

Install

dotnet add package PlcComm.KvHostLink

Connect

using PlcComm.KvHostLink;

var options = new KvHostLinkConnectionOptions("192.168.250.100", 8501);
await using var client = await KvHostLinkClientFactory.OpenAndConnectAsync(options);

This opens a queued client, which is the recommended surface for normal application code.

First read (step by step)

using System;
using PlcComm.KvHostLink;

var options = new KvHostLinkConnectionOptions("192.168.250.100", 8501);
await using var client = await KvHostLinkClientFactory.OpenAndConnectAsync(options);

ushort dm0 = (ushort)await client.ReadTypedAsync("DM0", "U");
Console.WriteLine($"DM0 = {dm0}");

Expected output:

DM0 = 123

Your number will match the current value stored in DM0 on your PLC.

First write

using System;
using PlcComm.KvHostLink;

var options = new KvHostLinkConnectionOptions("192.168.250.100", 8501);
await using var client = await KvHostLinkClientFactory.OpenAndConnectAsync(options);

const string testAddress = "DM100";
ushort original = (ushort)await client.ReadTypedAsync(testAddress, "U");

try
{
    await client.WriteTypedAsync(testAddress, "U", (ushort)1234);
    ushort readback = (ushort)await client.ReadTypedAsync(testAddress, "U");
    Console.WriteLine($"{testAddress} = {readback}");
}
finally
{
    await client.WriteTypedAsync(testAddress, "U", original);
}

Only write to a test address that is safe for your machine and program.

Confirm success

  1. The connection opens without a timeout.
  2. The first read prints a value for DM0.
  3. The write example prints the value written to DM100.
  4. The finally block restores the original test-register value.

If it does not work

Symptom Check
The connection fails immediately. Default port is 8501, not 1025; double-check the connection node port.
Reads fail while you are trying the first example. Start with DM word reads; do not start with timer/counter or expansion buffer access.
Timer/counter preset writes return E1. Timer/Counter preset writes (WS/WSS) are only supported on KV-8000/7000-series.

Next pages

Continue with Usage guide, then check Supported registers for device families and address forms.