Latest communication verification
This page keeps the current public summary only. Older detailed notes are not kept in the public documentation set.
Current Retained Summary
- last refreshed:
2026-05-02 - verified profile groups: direct
TOYOPUC-Plus, relayNano 10GX, directPC10G - verified public surface: queued connection, plain reads/writes, typed reads/writes, mixed snapshots, FR helpers, relay helpers
- recommended first public test:
P1-D0000andP1-M0000
Latest Direct PC10G Result
The latest direct toyopuc:pc10g:pc10 refresh was run on 2026-05-02 against
192.168.250.100:1025 over TCP.
- release build:
OK - full
SmokeTestsuite:ok=212 skip=0 ng=0 - restored word write:
P1-D0100 0x0000 -> 0x1234 -> 0x0000 - restored bit write:
P1-M0000 0 -> 1 -> 0 - 60-second
SoakMonitor:polls=60 ok=60 ng=0 reconnects=0 sessions=1
Practical Public Conclusions
TOYOPUC-Plusis the cleanest first-run path for prefixed word and bit access- relay
Nano 10GXremains a supported public path, but keep relay hops out of the first beginner test - direct
PC10Gremains supported, but profile-specific range limits matter more there than on the basicTOYOPUC-Pluspath
Current Cautions
- exact writable ranges depend on profile and hardware
FRsupport is profile-dependent and should not be the first smoke test- keep range-sweep and protocol-detail evidence out of the public user path
Where Older Evidence Went
This public page keeps only the current summary. Detailed historical evidence,
including the reproducible command log for the 2026-05-02 direct PC10G
smoke/soak refresh, is retained as maintainer notes.